09.91

3 Operating Sequences

3.1.5 Zero offset

b)External zero offset

The ºExternal zero offsetº values for the X and Z (and Q1,Q2,..) axes are transferred from the PLC.

These values can also be displayed on the screen

Sequence of operation

SETTING

DATA

Press the ºSETTING DATAº softkey

in any mode ...

EXT.-

ZO

... and then the ºEXT.ZOº softkey.

((Bild 810T/20 einmontieren))

This display appears on the screen. You can now read the values for ªG58º and ªG59º for the X, Z axes (and Q1,Q2 ... axes,if present), but you cannot change them.

The ºExternal zero offsetº is defined via machine data.

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

3-21

SINUMERIK 810T, GA3 (BN)

Page 120
Image 120
Siemens manual Bild 810T/20 einmontieren, External zero offset, Press the ºSETTING DATAº softkey Any mode