09.91

3 Operating Sequences

3.1.6 Setting data: ºR PARAMETERSº, ºSPINDLEº, ºAXIALº, ºANGLE OF ROTATIONº, ºSCALE MODIFICAT.º

or

3

3

L

L

...

 

...

· · ·

You can call up further screen forms with input fields for other R parameters with the page up/down keys ...

or

... you can call up an input screen form or a particular R parameter using the alphanumeric keys and the search key (º33º in example, ºRº need not be entered).

Enter the value for the selected R parameter with the numerical keys.

Subsequently, you can transfer the value into the input field with the input key.

ºSPINDLEº setting data

Using an input screen form, you can enter/modify the following spindle data via ºSETTING

 

Standard

Maximum

Input

Designation

setting data

input

unit

 

(delivery

value

 

 

state)

1)

2)

 

 

 

 

Smoothing constant with threading

0

5

-

 

 

 

 

Progammed spindle speed limitation

0

16000

rev / min

 

 

 

 

Oriented spindle stop

0

359.9

1 / 10 degree

 

 

 

 

 

Spindle speed limitation (absolute)

0

16000

rev / min

 

 

 

 

1) The ºMaximum input valueº is fixed in MD.

2) The ºInput unitº is fixed in MD:

you can also use 0.1 rev/min instead of rev/min.