3 Operating Sequences 09.91
3.1.6 Setting data: ”R PARAMETERS”, ”SPINDLE”, ”AXIAL”, ”ANGLE OF ROTATION”, ”SCALE MODIFICAT.”
Enter the value for the selected angle of rotation
with the numeric keys.
Subsequently, you can transfer the value into the
input field with the input key.
... ...
• • •
”SCALE MODIFICATION” setting data
Operate the ”SETTING DATA” softkey in any
operating mode.
Operate the ”SCALE MODIFICATION” softkey.
Extend the softkey menu displayed using the ETC
key to the right below the display.
Sequence of operation for ”SCALE MODIFICATION” setting data
SCALE
MODIF.
SETTING
DATA
The ”SETTING DATA SCALE MODIFICATION” input screen form appears in ”AUTOMATIC”
mode.
The following values defaulted by the program appear:
The “scale factor” (magnification or reduction) for:
Channel 1 : P ... (e. g. ”2” signifies 2 x magnification;
”0.5” signifies reduction by half)
Channel 3 : P ...
The “scale centre” (reference point) :
Axis 1 : X ...
Axis 2 : Z ...
..
..
3-32 © Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02
SINUMERIK 810T, GA3 (BN)