Siemens 810T manual 5011, Setting data bits, Explanation of setting data structure, Setting Bits

Models: 810T

1 312
Download 312 pages 8.21 Kb
Page 181
Image 181

3 Operating Sequences

09.91

3.1.15 Data input/data output

3.1.15.1 Setting data bits

The setting data - from byte No. 5000 to 5029 - each consist of 8 bits: No. 0 to No. 7.

These setting data serve for the matching of Interfaces 1 and 2, for the connection of different devices.

Explanation of setting data - structure:

(e.g. for setting data ( SD ) 5011)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5011

 

1

1

 

0

0

0

1

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

Bit pattern of the byte of

 

 

 

 

 

 

 

 

Setting data no.

 

 

 

 

 

 

 

 

 

 

 

setting data 5011

 

 

 

 

 

 

 

 

 

 

 

 

possible bit statuses:

º0º= Bit is not set º1º= Bit is set

Bit no.

Using an input form on the CRT you can enter the desired bit pattern for any byte in the range 5000 to 5029

Sequence of operation

SETTING

DATA

Operate the ºSETTING DATAº softkey in any of the operating modes.

Using the ETC key, extend the displayed softkey menu.

SETTING

BITS

Using the softkey, select the ºSETTING BITSº function.

3-78

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

SINUMERIK 810T, GA3 (BN)

Page 181
Image 181
Siemens 810T manual 5011, Setting data bits, Explanation of setting data structure, Setting Bits