11.90

3 Operating Sequences

3.2.5 ºTEACH INº

...

N

The blocks entered can be traversed using the ºProgram startº key.

You can delete the blocks not required by entering the block no. ºN ...º, and operating the delete key.

Blocks traversed correctly remain - as entered - in the memory. They do not have to be acknowledged.

3.2.6ºPLAYBACKº

Using the ºPLAYBACKº function in the ºAUTOMATICº operating mode, you can program linear movements.

The position values are approached at JOG traverse rate. Positions traversed to are transfer- red into the program memory.

The blocks entered are transferred into the program selected in the ºAUTOMATICº basic display.

ºTEACH INº and ºPLAYBACKº can be used alternately for generating a part program. When changing from ºAUTOMATICº mode to ºJOGº or ºINC ...º mode the ºTEACH INº and ºPLAYBACKº functions are retained.

After switching back from ºJOGº or ºINC ...º to ºAUTOMATICº , ºTEACH IN / PLAYBACKº must be reselected.

Sequence of operation

At least one complete part program block must be entered and traversed.

1, 10, 100,

Set the mode selector switch on the external machine control panel to one of the following symbols:

JOG

INC ...

1 000, 10 000

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

3-117

SINUMERIK 810T, GA3 (BN)

Page 223
Image 223
Siemens 810T manual 6 ºPLAYBACKº, Jog, Inc