Siemens 810T manual 2064, 2065, 2066, 2067, 2068

Models: 810T

1 312
Download 312 pages 8.21 Kb
Page 261
Image 261

11.90

4 Monitoring Functions

4.6

Listing of the alarms/alarm description

Alarm No.

2064

 

Alarm Text:

ºProgram error round (rotary) axisº

 

 

Reason:

If you round to either a half or full degree on a circular axis, the control

 

will monitor whether the programmed positions correlate with the

 

rounding.

Effect:

± Inhibiting of NC START

 

± The programmed move in the block is not executed.

Remedy:

Program the correct rotary axis position

Explanation:

In the JOG, INC modes, the control automatically rounds to valid

 

values. In the AUTOMATIC or MDI AUTOMATIC modes, the control

 

only monitors the programmed positions, without rounding itself.

 

 

Alarm No.

2065

 

Alarm Text:

ºPosition behind SW overtravel switchº

 

 

Reason:

The programmed block end-point lies behind the software limit switch.

Effect:

± Inhibiting of NC START

 

± The programmed move is not executed

Remedy:

Correct program

 

 

Alarm No.

2066

 

Alarm Text:

ºThread lead increase / decreaseº

 

 

Reason:

A thread lead increase or decrease of more than 16 mm / rev

 

(0.6 inch/rev) has been programmed.

Effect:

Inhibiting of NC START

Remedy:

Program a smaller thread lead increase / decrease

 

 

Alarm No.

2067

 

Alarm Text:

ºMax. speed =0º

 

 

Remarks:

Alarm only on commissioning

 

 

Alarm No.

2068

Alarm Text:

ºPos. behind working areaº

 

 

Reason:

The programmed block endpoint lies, in one or more axes, outside the

 

working area limits.

Effect:

± Inhibiting of NC START

 

± The programmed move is not executed

Remedy:

± Check working area limits (plus and minus)

 

± Alter working area limits in program with G25/G26

 

 

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

4-19

SINUMERIK 810T, GA3 (BN)

Page 261
Image 261
Siemens 810T manual 2064, 2065, 2066, 2067, 2068