2 Operation

09.91

2.1.1 SINUMERIK 810T operator interface with integrated machine control panel

2.1.1.2 Display panel

Symbols

LED displays

View of the display panel

ªAlarmº display

?

?

·The red LED lights up whenever there is a signal from the diagnostics monitor. The CRT display shows you the relevant message no. and the message text (2nd line of display).

·The message numbers are explained in the Alarm list in Section 4 of this Operator©s Guide.

·The LED is extinguished when the message has been acknowledged:

with acknowledge key

(Section 2.1.1.5)

with RESET key

(Section 2.1.1.6 or 2.1.2.1).

With certain messages, the display is only extinguished when the cause of the fault has been cleared (Section 4).

ªOut of positionº display

· The green LED is bright when at least one axis is moving.

·The LED is extinguished when all axes have reached their command

 

positions.

If the display

does not extinguish after traversing, the drift has exceeded the

permissible value. You must carry out drift compensation.

DIAGNOSIS

Press the ºDIAGNOSISº softkey.

Extend the softkey menu with the ETC key at the right below the screen.