3 Operating Sequences

09.91

3.2.3 Influencing ºAUTOMATICº operation

Using the softkey functions in this display, you can load files from the diskette into the NC as well as create, extend or delete them on the diskette (remote operation functions). Besides that you can call for the directory of the diskette (ªDIRECTORYº).

The "Data type" field indicates the program currently being transmitted via the RS232C (V.24) interface.

Remote operation functions:

The remote operation functions are used for program saving and program management on diskettes and they support the preparations for program sequencing (OPS). They are designed in such a way that the ordering principle required for OPS

"1 file = 1 main program + an unlimited number of subroutines" and "file name = main program name"

must inevitably be adhered to.

This means: When a main program is transferred, a new file with the same name is opened on the diskette and when subroutines are transferred, they are appended to an existing file.

The same general rule applies to all remote operation functions: First fill in the input fields required, then press the softkey for the desired function

Sequence of operation

NEW

Creating a new file:

FILE

 

 

 

 

Using the "NEW FILE" softkey, you open the NC-xxxx file (xxxx = 4-digit

 

 

 

 

 

 

number) on diskette.

 

 

 

The main program "%xxxx" is transferred from the NC part program

 

 

 

memory into this file on diskette.

 

 

 

You can only enter the file number, the main program number is

 

 

 

 

 

 

automatically set to the same value. Entering subroutine numbers is not

 

 

 

affected by this.

 

 

 

Note:

 

 

 

If there already exists a file with the same name on the diskette, an

 

 

 

error message is given by the disk drive unit and the command is not exe-

 

 

 

cuted (see also Section 4.6, Alarm 33 ªDifferent programs same No.

 

 

 

(RS232C (V.24))º).

 

 

 

Example: File = 10 The file NC-0010 is opened on diskette, the %10

 

 

 

main program is transferred from the NC part

 

 

 

program memory into this file.

3-106

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

SINUMERIK 810T, GA3 (BN)

Page 211
Image 211
Siemens 810T manual Remote operation functions, New, Creating a new file, File