11.91

4 Monitoring Functions

4.6

Listing of the alarms/alarm description

Alarm No.

14

 

 

Alarm Text:

ºRAM error memory moduleº

 

 

Remarks:

Alarm only on commissioning

 

 

Alarm No.

16

 

 

Alarm Text:

ºParity error RS232C (V.24)º

 

 

Reason:

The last character transferred has incorrect parity.

Effect:

RS232 transfer is interrupted; the last block is not stored

Remedy:

± Check setting data 5011/5013/5019/5021

 

±

Test external device

Explanation:

The alarm only appears when the setting data ºwith parity bitº is set.

 

 

Alarm No.

17

 

 

Alarm Text:

ºOverflow error RS232C (V.24)º

 

 

Reason:

Transfer speed is not correct

Effect:

± Data transfer is interrupted

 

±

The last block is not stored

Remedy:

± Check setting data 5011/5013/5019/5021

 

±

Check transfer speed (Baud rate)

 

 

Alarm No.

18

 

 

Alarm Text:

ºFrame error RS232C (V.24)º

 

 

Reason:

± Number of stop bits is incorrect

 

±

Baud rate is incorrect

 

±

Number of data bits is incorrect

Effect:

± Data transfer is interrupted

Remedy:

± The last block is not stored

 

±

Check setting data 5011/5013/5019/5021

 

±

Test external device

 

 

Alarm No.

19

 

 

Alarm Text:

ºI/O device not ready RS232C (V.24)º

 

 

Reason:

DSR signal has low level.

Effect:

No data are read in.

Remedy

±

Start external device

 

±

Do not use DSR (isolate cable)

 

 

Alarm No.

20

 

 

Alarm Text:

ºPLC alarm memory not formattedº

 

 

Remarks:

Alarm only on commissioning

 

 

 

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

4-7

SINUMERIK 810T, GA3 (BN)

Page 249
Image 249
Siemens 810T manual 11.91