4 Monitoring Functions

09.91

4.6 Listing of the alarms/alarm description

 

Alarm No.

22

 

 

 

 

Alarm Text:

ºTime monitoring RS232C (V.24)º

 

 

Reason:

Delay of 60 sec. for data transfer exceeded

Remedy:

±

Check external device

 

±

Check cable

 

±

Check setting data 5017 and 5025

 

± Set bit 0 to º1º.

 

 

 

Alarm No.

23

 

 

 

 

Alarm Text:

ºChar. parity error RS232C (V.24)º

 

 

Reason:

Punched tape dirty or damaged

Effect:

± RS232C (V.24) transfer is interrupted

 

± the last block is not stored

 

With block transfer: faulty cable

 

±

RS232C (V.24) transfer is stopped

Remedy:

Check punched tape

 

With block transfer: Check connection

Explanation:

Depending upon the definition of the start of program º%º or ºEORº,

 

the NC automatically establishes the ISO or EIA code upon receipt of

 

this character, and establishes the character parity.

 

With block transfer: Each character of a data block is checked for

 

character parity and the block itself for BCC.

 

When checking the characters or the block, it was established that one

 

character did not have the set parity.

 

 

Remarks:

Do not switch off control, data may be lost.

 

 

 

Alarm No.

24

 

 

 

 

Alarm Text:

ºInvalid EIA character RS232C (V.24)º

 

 

Reason:

An EIA character with the correct parity was read in, but the character

 

was not defined in EIA code

Effect:

± Data transfer is interrupted

 

± The last block is invalid

Remedy:

check punched tape:

 

Setting data 5026 (EIA code for º@º) and

 

Setting data 5027 (EIA code for º:º)

Explanation:

The º=º character in EIA code is not defined, and the following data

 

cannot be read in:

 

%TEA1

(NC machine data)

 

%TEA2

(PLC machine data)

 

%TEA5

(Drive machine data for SERCOS interface)

 

%TEA6

(Drive machine data for parallel interface)

 

%RPA

(R parameters)

 

%ZOA

(Zero offsets)

 

%TOA

(Tool offsets)

 

%PCA

(PLC Alarm text)

 

Main programs and subroutines with R parameter calculations

 

 

 

 

4-8

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

SINUMERIK 810T, GA3 (BN)

Page 250
Image 250
Siemens 810T manual TEA1, TEA2, TEA5, TEA6