3 Operating Sequences

11.90

3.1.15 Data input/data output

 

Notes:

When inputting from punched tape, the input data are checked for simple errors.

All characters in punched tape code have a common identification character:

·in ISO code there is always an even hole count

·in EIA code there is always an odd hole count

The control automatically identifies the correct code when reading the first º%º (ISO) or ºEORº (EIA)!

The criterion ºOdd hole countº or ºEven hole countº is used for character parity checking from the second character in the program onwards.

As a further check, if a program already in the program memory is read in again, a complete program comparison is carried out.

When an error is recognized, reading in is stopped and the error displayed on the CRT.

3.1.15.3 Data output

Sequence of operation

DATA DATA

IN-OUT OUTPUT

In any of the operation modes:

PRESET / JOG / AUTOMATIC /

INC 1 .... INC 10 000 / REFPOINT,

operate the ºDATA IN-OUTº softkey and subsequently ºDATA OUTPUTº.

This input form appears, with the input field for ºoutput interfaceº identified in inverse video.

((Bild 810T/38 einmontieren))

1

F

or

2

D

Now enter:

º1º ( for output via Interface 1 ) or º2º ( for output via Interface 2 ) and store it using the input key.

PART

PROGRAM

Using the softkey, now select, for example, the ºPART

PROGRAMº function.

3-82

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

SINUMERIK 810T, GA3 (BN)

Page 185
Image 185
Siemens manual Data output, Bild 810T/38 einmontieren, Data Data IN-OUT Output, Any of the operation modes