09.91

4 Monitoring Functions

4.6

Listing of the alarms/alarm description

Alarm No.

2078

 

Alarm Text:

ºIncorrect input parameterº

 

 

Reason:

± Programmed parameter sequence not allowed

 

± Parameter sequence not complete for the described contour

Effect:

As for alarm 2072

Remedy:

As for alarm 2072

 

 

Alarm No.

2081

 

Alarm Text:

ºCRC not allowedº

 

 

Reason:

With TNRC/CRC selected (G41/G42), the following functions cannot

 

be programmed:

 

G33, G34, G35; G58; G59, G92, M19 S ...

Remedy:

First program cancellation of TNRC/CRC

 

with G40 or D0

 

 

Alarm No.

2082

 

Alarm Text:

ºCRC plane not determinableº

 

 

Reason:

The axes for the selected CRC/TNRC plane do not exist

Remedy:

Select correct plane with G16

 

 

Alarm No.

2087

 

Alarm Text:

ºCoordinate rotation not allowedº

 

 

Remedy:

Check NC program

 

 

Alarm No.

2088

 

Alarm Text

ºBattery alarm abs. submod. 1º

 

 

Reason:

Battery voltage is too low. Battery test is performed every 10 min.

Remedy:

Replace battery module on absolute encoder module 1 while the

 

control is switched on.

 

 

Alarm No.

2089

 

Alarm Text

ºBattery alarm abs. submod. 2º

 

 

Reason:

Battery voltage is too low. Battery test is performed every 10 min.

Remedy:

Replace battery module on absolute encoder module 2 while the

 

control is switched on.

 

 

Alarm No.

2152

 

Alarm Text:

ºSpindle speed too highº

 

 

Reason:

The actual spindle speed is higher than that set in machine data.

 

± Program a smaller S value

 

± G92 S ... with v constant

 

± Search for a block number in the ºEDITº mode (ºAUTOMATICº

 

mode)

Remedy:

Check or inform Service

 

 

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

4-21

SINUMERIK 810T, GA3 (BN)

Page 264
Image 264
Siemens 810T manual 2078, 2081, 2082, 2087, 2088, 2089, 2152