7 Interfacing to the Machine

09.91

7.3.2 Definition of R parameters as cycle machine data, cycle setting data

7.3.2Definition of R parameters as cycle machine data, cycle setting data

To protect parameters (R110 to R199) used for the measuring cycles against inadvertent modification, the parameters can be defined as:

·Cycle machine data (CMD) or

·Cycle setting data (CSD)

The definition is made via general NC machine data 14 to 17.

R parameter

110 to 199 per channel

Cycle MD

Cycle SD

Cycle MD

MD 14 = Cycle MD from

Rparameter number.....

MD 16 = Cycle SD from

Rparameter number.....

MD 17 = Cycle SD to

Rparameter number.....

MD 15 = Cycle MD to

Rparameter number.....

Where overlaps occur, SDs are dominant. Any allocation possible.

Definition of area limits with general NC MC 14 to 17.

7-6

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

SINUMERIK 810T, GA3 (BN)

Page 295
Image 295
Siemens 810T manual Cycle MD Cycle SD, Definition of area limits with general NC MC 14 to