4 Monitoring Functions

11.90

4.6 Listing of the alarms/alarm description

 

Alarm No.

2072

 

 

Alarm Text:

ºIncorrect input valueº

 

 

Reason:

The input value for the contour path calculation cannot be calculated.

Effect:

The faulty block is not simulated or executed.

Remedy:

Input the correct value for the contour path

 

 

Alarm No.

2073

Alarm Text:

ºNo intersection pointº

 

 

Reason:

Calculation of the contour path gives no intersection point with the

 

values programmed.

Effect:

As for alarm 2072

Remedy:

As for alarm 2072

 

 

Alarm No.

2074

 

 

Alarm Text:

ºIncorrect angle valueº

 

 

Reason:

± An angle greater than or equal to 360 degrees was programmed

 

±

The angle value has no meaning for the described contour

Effect:

As for alarm 2072

Remedy:

As for alarm 2072

 

 

Alarm No.

2075

 

 

Alarm Text:

ºIncorrect radius valueº

 

 

Reason:

± Radius value too large

 

±

Radius value not allowed for the described contour

Effect:

As for alarm 2072

Remedy:

As for alarm 2072

 

 

Alarm No.

2076

 

 

Alarm Text:

ºIncorrect G02 / G03º

 

 

Reason:

Direction of circle for the described contour is not possible

Effect:

As for alarm 2072

Remedy:

As for alarm 2072

 

 

Alarm No.

2077

 

 

Alarm Text:

ºIncorrect block sequenceº

 

 

Reason:

Several blocks are needed for the calculation of the contour path:

 

±

Block sequence not correct

 

±

Insufficient information (underdefined)

Effect:

As for alarm 2072

Remedy:

As for alarm 2072

 

 

 

4-20

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

SINUMERIK 810T, GA3 (BN)

Page 263
Image 263
Siemens 810T manual 2072, 2073, 2074, 2075, 2076, 2077