3 Operating Sequences

09.91

3.2.3 Influencing ºAUTOMATICº operation

 

User notes on ºRAPID OVERRIDEº :

During processing of a new NC program the feedrate override switch can be enabled with the keyswitch.

The following rapid overide values can be set with the ºfeedrate override selector switchº on the customer operator panel.

Setting

Override value in %

 

 

1

1

2

10

3

50

4

100

 

 

This table is only applicable when the ºRapid override switch presentº machine data is set. When this is not the case, the setting for the ºFeedrate override switchº applies for rapid override, with a limitation of 100%!

DEC-SBL

YES-NO

You select, for example, the ºDECODING SINGLE BLOCKº softkey function.

Display:

Decoding single block

When the function is activated with ºYESº, the control generates the ºDecoding single block activeº signal.

The signal is active at the end of the block in the running part program, which is running through with the decoding signal present.

Now operate the ºProgram startº key. The decoding single block is now processed.

Operate the ºProgram startº key once more. The next decoding single block is processed ... etc.

3-96

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

SINUMERIK 810T, GA3 (BN)

Page 199
Image 199
Siemens 810T manual Dec-Sbl Yes-No