6 Data Interfaces

01.93

6.4 Device connection data

Siemens Programmer

PG 685/675/670/730/750

Interface S5 PLC

Cable Order No.: 6FC9 340-8G 6FC9 344-4R (PG 750/730 only)

Device data

 

 

Interface:

20 mA current

 

loop

Transfer rate:

9600 baud

Character format:

1

Start bit,

 

7

Data bits,

 

1

Parity bit (even

 

parity),

 

2

Stop bits

Operating conditions

 

 

For PLC programming the PG 685/675/ 670/750 programmer should be connected directly to interface 1 (20 mA current loop interface) on the SINUMERIK 810T.

(If cable 6FC9340-8G is used with the PG 750, the supplied adaptor must be used)

Siemens Programmer PG 675/685

Interface Printer

Cable Order No.: 6FC9 344-1A.

Device data

 

 

Interface:

RS232C (V.24)

Transfer rate:

1200 baud

Character format:

1

Start bit

 

8

Data bits

 

2

Stop bits

Operating conditions

Siemens programmer PG 615 U with PG 615 adapter and power pack

Interface PLC

Cable Order No.: 6FC9 340-8H.

Device data

 

 

Interface:

20 mA current

 

loop

Transfer rate:

9600 baud

Character format:

1

Start bit

 

7

Data bits

 

1

Parity bit

 

(even parity)

 

2

Stop bits

Operating conditions

For PLC programming the PG 615 program- mer is connected via the adapter and a cable to interface 1 (20 mA current loop) on the SINUMERIK 810T.

Archiving of NC cycles and programs onto disk, and the transfer to and from the NC and the creation of programs is possible with the PG 675/685.

For data transfer, the PG 675/685 should be connected from the printer interface to an RS232C (V.24) interface on the SINUMERIK 810T.

6-6

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

SINUMERIK 810T, GA3 (BN)