The tables in this section provide detailed troubleshooting information.

The Power does not come on

Cause

Relevant

Check *

Action

Unit

 

 

 

 

 

 

 

Unplugged

None

Visual check

Insert the ac

from outlet

 

 

plug into the

 

 

 

outlet.

 

 

 

 

AC power

LVPS

Visual check

Insert the ac

unplugged at

 

 

cable into

power supply

 

 

power supply.

 

 

 

 

Power switch

None

Visual check

Turn the power

is OFF

 

 

switch on.

 

 

 

 

Power supply

None

Visual check

Connect the

power

 

 

connector.

distribution

 

 

 

board

 

 

 

connection

 

 

 

failure

 

 

 

 

 

 

 

Power supply

LVPS

Tester check

Replace the

output voltage

 

the LVPS

power supply.

failure

 

(+5V +12V,

 

 

 

+24V, GND)

 

 

 

 

 

Power

Power

Tester check

Replace the

distribution

distribution

(+5V, GND)

failed power

board

board

 

distribution

 

 

 

board.

 

 

 

 

MFD

MFD

None

If problem still

controller

controller

 

exists, replace

board

board

 

MFD controller

 

 

 

board.

 

 

 

 

*Check explains how to check the failed item.To do a visual check observe the part or observe the offline test display on the front panel. To do a tester check, check the voltage levels of the relevant units. (See Connector Locations.)