4036-304

Maintenance Tools

The following table describes the tools necessary for the maintenance of this scanner.

Name

Description

 

 

Flathead screwdriver

Idler pulley module screw

 

 

Phillips screwdriver (magnetic)

Nominal No.2 M3, M4

 

 

Nut driver

6 mm

 

 

Digital voltmeter

With 0.01 V range

 

 

Chip Puller

Puller for main scanner board chip

 

 

Removals

Parts Replacement

1.Clean the disassembly and assembly location.

2.Turn off the power switch and remove the AC plug from the outlet before disassembly and assembly.

3.Follow the disassembly and assembly procedures. Never loosen the screws of parts that must not be disassembled. These screws have a red coating.

4.Store the disassembled parts in a clean place to avoid loss.

5.After replacement, check the contacts and spare part mounting.

6.Assemble in the reverse order of disassembly.

3-2Service Manual