Scan module does not move to lock position

Cause

Relevant

Check

Action

Unit

 

 

 

 

 

 

 

Home

CCD board

Tester check

Replace the

position

 

 

CCD PCBA.

sensor board

 

 

 

failure

 

 

 

 

 

 

 

Motor-main

None

Visual check

Connect the

control PCBA

 

 

connector.

connection

 

 

 

failure

 

 

 

 

 

 

 

Motor failure

Carrier motor

Visual check

Replace the

 

 

 

carrier motor.

 

 

 

 

Power supply-

None

Visual check

Connect the

main control

 

 

connector.

board

 

 

 

connection

 

 

 

failure

 

 

 

 

 

 

 

Power supply

Power supply

Tester check

Replace the

fails.

 

(+24V, GND)

power supply.

 

 

 

 