5056-XXX

HCF paper level sensor removal

1.Remove the four screws from the transfer cover, and remove the cover.

2.Remove the two screws from the sensor, and remove the cover.

3.Remove the connector and screw from paper level sensor, and remove the sensor.

HCF power supply removal

1.Move the paper tray upward.

2.Disconnect the power cord.

3.Remove the front cover.

4.Remove the two screws from the power supply cover, and remove the cover.

5.Remove the four screws from the power supply unit, and remove the unit.

6.Remove the two screws from the DC-DC converter, and remove the converter.

4-62Service Manual