LG Electronics LAU121CNM, LAN121CNM, LA121HPMI service manual Piping Length and Elevation

Models: LA121HPMI LAU121CNM LAN121CNM LAN121CNM, LAU121CNM, LA121HPMI, LA121HPMO, LAN121HNM, LAU121HNM, LA121CPMI, LA121CPMO

1 71
Download 71 pages 12.57 Kb
Page 16
Image 16

Installation

PipingLengthandElevation

Capacity

Pipe Size

Standard

Max.

(Btu/h)

Suction

Evap

Length

Elevation

m(ft)

B m(ft)

 

12k

Ø12.7(1/2")

Ø6.35(1/4")

7.5(25)

7.5(25)

Indoor unit

 

 

Outdoor unit

 

 

A

 

A

 

 

 

 

 

B

Outdoor unit

Indoor unit

B

 

 

 

 

 

Max.

Additional

length

Refrigerant

A m(ft)

g/m(oz/ft)

15(49)

20(0.22)

 

Outdoor unit

Oil trap

A

 

Indoor unit

B

 

In case more than 5m(16.4ft)

Capacity is based on standard length and maximum allowance length is on the basis of reliability.

Oil trap should be installed every 5~7meters (16.4~23.0ft).

16Room Air Conditioner

Page 16
Image 16
LG Electronics LAU121CNM, LAN121CNM, LA121HPMI service manual Piping Length and Elevation