Installation
![](/images/new-backgrounds/1041892/4189231xi2.webp)
Piping
Length
and
Elevation![](/images/new-backgrounds/1041892/4189231xi7.webp)
![](/images/new-backgrounds/1041892/4189231xi8.webp)
![](/images/new-backgrounds/1041892/4189231xi9.webp)
![](/images/new-backgrounds/1041892/4189231xi10.webp)
![](/images/new-backgrounds/1041892/4189231xi11.webp)
![](/images/new-backgrounds/1041892/4189231xi12.webp)
![](/images/new-backgrounds/1041892/4189231xi13.webp)
![](/images/new-backgrounds/1041892/4189231xi14.webp)
![](/images/new-backgrounds/1041892/4189231xi15.webp)
![](/images/new-backgrounds/1041892/4189231xi16.webp)
![](/images/new-backgrounds/1041892/4189231xi17.webp)
![](/images/new-backgrounds/1041892/4189231xi18.webp)
![](/images/new-backgrounds/1041892/4189231xi19.webp)
Capacity | Pipe Size | Standard | Max. | ||
(Btu/h) | Suction | Evap | Length | Elevation | |
m(ft) | B m(ft) | ||||
| |||||
12k | Ø12.7(1/2") | Ø6.35(1/4") | 7.5(25) | 7.5(25) | |
Indoor unit |
|
| Outdoor unit |
| |
| A |
| A |
| |
|
|
|
| ||
B | Outdoor unit | Indoor unit | B |
| |
|
|
|
|
Max. | Additional |
length | Refrigerant |
A m(ft) | g/m(oz/ft) |
15(49) | 20(0.22) |
| Outdoor unit |
Oil trap | A |
| |
Indoor unit | B |
|
In case more than 5m(16.4ft)
•Capacity is based on standard length and maximum allowance length is on the basis of reliability.
•Oil trap should be installed every 5~7meters (16.4~23.0ft).
16Room Air Conditioner