Service Manual 37
Self-diagnosis FunctionOperation
Display Function1. Heating Model 2. Cooling Model
• Cooling, Soft Dry, Fan, Heating • Cooling, Soft Dry, Fan
• Hot-start, Deice
Operation Indicator
Deicer Indicator
Operation Indicator
Compressor on Indicator
3sec 3sec 3sec
(once)
Error
Code
1
Error Display LED
(Indoor body operation LED) Error contents
• Indoor room temperature
thermistor open/short
• Indoor pipe temperature
thermistor open/short.
• Indoor Thermistor
assembly check
SVC check point