DECK MECHANISM ADJUSTMENT
2.Preparation for Adjustment (To set the Deck Mechanism of the loading state
without inserting a cassette tape).
1)Unplug the power cord from the AC outlet.
2)Disassemble the Top Cover and Plate Assembly Top.
3)Plug the power cord into the AC outlet.
4)Turn the power S/W on and push the Lever Stopper of the Holder Assembly CST to the back for loading the
cassette without tape.
Cover the holes of the End Sensors at the both sides of the Chassis to prevent a light leak.
Then the Deck Mechanism drives to the Stop Mode. In this case, the Deck Mechanism can accept inputs of each mode, however the Rewind and Review operation can not be performed for more than a few seconds because the
3. Checking Torque
Purpose: To insure smooth transport of the tape during each mode of operation.
If the tape transport is abnormal, then check the torque as indicated by the chart below.
Test Equipment/ Fixture | Test Conditions | Checking Method | |
(Mechanism Condition) | |||
|
|
•Torque Gauge(600g/cm ATG) • Play (FF) or Review (REW) Mode • Perform each Deck Mechanism mode without
• Torque Gauge Adaptor |
|
| inserting a cassette tape(Refer to above No.2 | |||
• Cassette Torque Meter |
|
| Preparation for Adjustment). | |||
|
| • Read the measurement of the | ||||
|
|
|
| Reels on the Cassette Torque Meter(Fig. | ||
|
|
| • Attach the Torque Gauge Adaptor to the Torque | |||
|
|
|
| Gauge and then read the value of it(Fig. | ||
|
|
|
|
|
|
|
Item |
| Mode | Test Equipment |
| Measurement Reel | Measurement Values |
|
|
|
|
|
|
|
Fast Forward Torque |
| Fast Forward | Cassette Torque Gauge |
| More than 400g/cm | |
|
|
|
|
|
|
|
Rewind Torque |
| Rewind | Cassette Torque Gauge |
| Supply Reel | More than 400g/cm |
|
|
|
|
|
|
|
Play |
| Play | Cassette Torque Meter |
| 40~100g/cm | |
|
|
|
|
|
|
|
Review Torque |
| Review | Cassette Torque Meter |
| Supply Reel | 120~210g/cm |
|
|
|
|
|
|
|
NOTE: |
| NOTE: |
|
|
|
The values are measured by using a Torque Gauge and Torque Gauge Adaptor with the Torque Gauge affixed.
The torque reading to measure occurs when the tape abruptly changes direction from Fast Forward to Rewind Mode, when quick braking is applied to both Reels.
• Torque Gauge (600g.cm ATG) | • Cassette Torque Meter |
Torque Gauge
Torque Gauge Adaptor
Reel Table
S
R
T- H
S
300 | |
0 | 50 |
250
200 |
|
150 | SRK |
| |
VIDEO | |
CASSETTE | |
TORQUE | |
METER |
|
VHT- |
|
303 |
|
K | |
SR | 0 |
| 50 |
| 100 |
| 150 |
| 200 |