MECHANISM TROUBLESHOOTING GUIDE

1.Deck Mechanism

A.

Auto REW doesn't work.

YES

Is the output of END sensor of

 

 

 

 

 

 

 

 

 

supply side "H"?

 

 

 

 

 

 

 

 

 

“H”: more than 3.5V

 

 

 

 

 

 

 

 

 

“L”: less than 0.7V~1V

 

NO

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is the Vcc. voltage of End

 

 

 

 

 

 

 

 

 

sensor 5V?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace the End sensor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

Is the voltage across IR LED

Replace the IR LED.

 

 

 

 

 

 

 

 

between 0.8~1.5V?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check the syscon power.

YES

Check the syscon circuit.

B.

No F/R modes.

YES

Is the present mode

F/R Mode?

NO

Is the mode SW assembled correctly? (refer to page 4-13.)

YES

Does the Capstan Motor rotate?

YES

Do the T/Up, Supply Reel rotate?

YES

Check the syscon circuit.

NO

Is the normal voltage supplied to the Capstan Motor Vcc1, Vcc2?

YES

Does terminal voltage(Vctl) of Capstan Motor supply side more than 4V?

YES

Replace the Capstan Motor.

NO

Check the servo, power circuits.

4-23

Page 60
Image 60
LG Electronics TL-AT130M service manual Mechanism Troubleshooting Guide