SECTION1 SUMMARY

LOCATION OF CUSTOMER CONTROLS

TERMINAL SIGNAL LEVELS

TERMINAL

 

 

 

 

SIGNAL LEVEL

 

IN/OUT

DESCRIPTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIH : 4

~ 5V

 

The input signal that makes

1. ALARM IN

 

 

 

 

 

 

 

 

VIL

: 0 ~ 0.6V

INPUT

 

 

 

 

 

 

 

 

‘Alarm Record’ work

 

 

 

 

 

 

 

 

 

 

 

T

: above 250 msec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIH : 4

~ 5V

 

Outputs whether ‘Alarm

 

 

 

 

 

 

 

 

 

 

2. ALARM OUT

 

 

 

 

 

 

 

 

VIL

: 0 ~ 0.6V

OUTPUT

 

 

 

 

 

 

 

 

Recording’ is working

 

 

 

 

 

 

 

 

T : ALARM REC STATE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.ALARM RESET

 

 

 

 

 

 

 

 

VIH : 4

~ 5V

 

The terminal that stops ‘Alarm

 

 

 

 

 

 

 

 

VIL

: 0 ~ 0.6V

INPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

: above 250 msec

 

Record’ in Auto mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIH : 4 ~ 5V

 

The input terminal to make

5. SERIES IN

 

 

 

 

 

 

 

 

VIL

: 0 ~ 0.6V

INPUT

 

 

 

 

 

 

 

 

 

 

 

T

: above 250 msec

 

‘Series Record’ work

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6. SERIES OUT

 

 

 

 

 

 

 

 

VIH : 4 ~ 5V

 

Output signal appears when the

 

 

 

 

 

 

 

 

VIL

: 0 ~ 0.6V

OUTPUT

tape reaches to end or deck is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

: above 250 msec

 

error in recording.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7. WARNING OUT

 

 

 

 

 

 

 

 

VIH : 4 ~ 5V

 

Outputs whether VCR deck is

 

 

 

 

 

 

 

 

VIL

: 0 ~ 0.6V

OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

error.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T : until any-key is pressed

 

 

 

 

 

 

 

 

 

 

 

 

 

VIH : 4 ~ 5V, VIL : 0 ~ 0.6V

 

The signal is output which is used by

8. TRIGGER OUT

 

 

 

 

 

 

 

 

8 msec : NTSC

OUTPUT

switching several cameras in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 msec : PAL

 

general space with using camera

 

 

 

 

 

 

 

 

 

 

 

 

multi-plexer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIH : 4 ~ 5V

 

As the terminal that outputs that tape

10. LOW TAPE OUT

 

 

 

 

 

 

 

 

VIL

: 0 ~ 0.6V

OUTPUT

remains less than 5 minutes in

 

 

 

 

 

 

 

 

recording, it isn’t output in ‘1-shot

 

 

 

 

 

 

 

 

 

 

 

T : below 5 min, end of tape

 

Record’.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIH : 4 ~ 5V

 

The terminal that makes ‘1-short

11. 1-SHOT REC IN

 

 

 

 

 

 

 

 

VIL

: 0 ~ 0.6V

INPUT

 

 

 

 

 

 

 

 

 

 

 

T

: above 250 msec

 

Record’ work in Auto mode

 

 

 

 

 

 

 

 

 

 

 

 

 

4, 9, 12. GND

-

0V

COMMON

1-4

Page 6
Image 6