NTI RACKMUX RACKMOUNT ANSI TERMINAL DRAWER

4. CONNECTOR PIN ASSIGNMENT

Table 6- Serial Port (Serial 1) Connector Pin Assignments (RS232C 9-pin connector)

 

Pin

 

Signal

 

Mnemonic Direction

 

 

 

1

 

 

Data carrier detect

 

DCD In

2

 

 

Receive data

 

RxD In

3

 

 

Transmit data

 

TxD Out

4

 

 

Data terminal ready

 

DTR Out

5

 

 

Signal ground

 

SGND

6

 

 

Data set ready

 

DSR In

7

 

 

Request to send

 

RTS Out

8

 

 

Clear to send

 

CTS In

 

Table 7- Serial Port (Serial 2) Connector Pin Assignments

 

(RS232C 9-pin connector)

 

 

 

 

Pin

 

 

Signal

 

 

Mnemonic Direction

 

1

 

 

Data carrier detect

 

DCD In

2

 

 

Receive data

 

RxD In

3

 

 

Transmit data

 

TxD Out

4

 

 

Data terminal ready

 

DTR Out

5

 

 

Signal ground

 

SGND

6

 

 

Data set ready

 

DSR In

7

 

 

Request to send

 

RTS Out

8

 

 

Clear to send

 

CTS In

Table 8- Printer Port Connector Pin Assignments (Compatible with the IBM PC parallel port)

 

Pin

 

Signal

 

Mnemonic Direction

 

 

 

1

 

 

-Strobe

 

Out

2

 

 

Data bit 0

 

Out

3

 

 

Data bit 1

 

Out

4

 

 

Data bit 2

 

Out

5

 

 

Data bit 3

 

Out

6

 

 

Data bit 4

 

Out

7

 

 

Data bit 5

 

Out

8

 

 

Data bit 6

 

Out

9

 

 

Data bit 7

 

Out

10

 

 

-Acknowledge

 

In

11

 

 

Busy

 

In

12

 

 

Paper end

 

In

13

 

 

Slct

 

In

14

 

 

-Auto feed XT

 

Out

15

 

 

-Error

 

In

16

 

 

-Init

 

Out

17

 

 

-Slctn

 

Out

18-25

 

 

Ground

 

Out

 

Table 9- 10Base T Connector Pin Assignments

 

(RJ45 8 pin female connector)

 

 

 

 

Pin

 

 

Signal

 

 

Direction

 

1

 

 

Transmit +

 

Out

2

 

 

Transmit -

 

Out

3

 

 

Receive +

 

In

6

 

 

Receive -

 

In

17

Page 21
Image 21