Network Technologies RACKMUX-T15 Default Configuration, Disp Setup Menu F2 General Setup Menu

Models: RACKMUX Series RACKMUX-T15

1 55
Download 55 pages 41.61 Kb
Page 12
Image 12

NTI RACKMUX RACKMOUNT ANSI TERMINAL DRAWER

2.1.4 Default Configuration

The terminal is delivered pre-configured with the following settings suitable for most RS232 serial console connections at 9600 baud using VT-100 emulation.

Disp SETUP Menu

F2 General SETUP Menu

Columns = Econ-80

Personality = VT 100

Cursor = Blink Block

Enhance = On

Screen Saver = Off

Status Line = Standard

Lines = 24

Scroll Speed = Jump

Background = Dark

Auto Scroll = On

Page Length = 1 x Lines

End of Line Wrap = On

Auto Page = Off

Rcvd CR = CR

Width change clear = Off

Monitor = Off

ANSI Reverse = Off

Attribute = Char

Display= LCD

 

F4 Comm SETUP Menu

F5 Misc SETUP Menu

Baud rate = 9600

Wprt Intensity = Dim

Data / Stop Bits = 8/1

Wprt Reverse = Off

Parity = None

Wprt Underline = Off

Rcv Hndshake = Xon/Xoff

Block End = US/CR

Xmt Hndshake = Xon/Xoff

Ptr Baud rate = 38400

Comm Mode = FDX

Ptr Data/Stop Bits = 8/1

XPC Handshake = On

Ptr Parity = None

Printer Selection = Off

Ptr Rcv Hndshake = Xon/Xoff

Multiple Sessions = Off

Ptr Xmt Hndshake = Xon/Xoff

Ethernet Mode = Off

Ptr Rcv = Off

Auto Connect = Off

 

F3 Keybd SETUP Menu

Keyclick = Off

Key Repeat = 5

Xmt Limit = None

Margin Bell = Off

Language = US

Keycode = ASCII

NRC = Off

Bell Volume = 2

NUM Start = Off

DEL Keypad = Dot/Del

F9 Lan Setup Menu

Local IP Address = {blank} Netmask = {blank} Gateway = {blank}

Remote IP 0..B Address ={blank} Port 0...B = 23

Term Type = vt100 Ethernet Node ID = (default}

For use with an Ethernet connection the following parameters need to be configured:

Display Setup (F1 in setup mode)

Page Length = 1*Lines (only required if ‘Multiple Sessions=On’)

Communications Setup (F4 in setup menu) Multiple Sessions = Off or On

Ethernet Mode = On Auto Connect = Off or On

‘Multiple Sessions=On’ should be set if multiple telnet sessions are required.

‘Auto Connect=On’ is used to prevent the need to press return to establish a telnet connection.

LAN Setup (F9 in setup mode)

Local IP Address = IP address of the terminal

Netmask = Netmask value for the network

Gateway = gateway address if required by the network

Remote IP 0 Address = IP address of first server Port = 23

Remote IP 1 Address = IP address of second server Port = 23

….

Remote IP B Address = IP address of twelfth server Port = 23

Term Type = Same as personality specified in General Setup menu

Ethernet Node ID = leave at default value

Note: If only one host is being connected to, all twelve Remote IP addresses and ports should be set to the same value.

Note: Eight separate telnet sessions are allowed if any columns other than Econ-80 is selected in Terminal Display Set- up. If Econ-80 is selected, the Multiple Sessions option allows twelve concurrent telnet sessions to be used.

8

Page 12
Image 12
Network Technologies RACKMUX-T15 Default Configuration, Disp Setup Menu F2 General Setup Menu, F3 Keybd Setup Menu