11. DC POWER OPTION

If the RACKMUX has been ordered with the DC Power option (“48V” at the end of the model number), a 3-terminal block has been provided for connection to a 36-72VDC 2A power source. The terminal block can be easily removed from under the protective bracket to make connections. Proper connections are indicated.

Note: Be sure to properly secure the terminal block to the RACKMUX after wire insertion.

An earth ground terminal has been provided for optional use.

REAR VIEW OF RACKMUX-T1548V

protective bracket

36-72VDC

Earth ground connection

Remove screws to remove terminal block

CAUTION: RISK OF ELECTRIC SHOCK

36-72VDC PRESENT ON DC POWER INPUT

Figure 15- RACKMUX with DC Power option

Remove screws to remove terminal block

Phillips screwdriver

terminal block

Power supply ground

Figure 16- Apply wires to terminal block