Lincoln Electric 300 DLX manual F-2CONNECTION DIAGRAMSF-2

Models: 300 D

1 56
Download 56 pages 9.16 Kb
Page 42
Image 42
F-2CONNECTION DIAGRAMSF-2

F-2CONNECTION DIAGRAMSF-2

RANGER 300 DLX / LN-25 WITH K624-1 42 VOLT REMOTE OUTPUT

CONTROL MODULE CONNECTION DIAGRAM

Manual background WARNING

Manual background Do not operate with panels open.

Manual background Disconnect NEGATIVE (-) BATTERY LEAD before servicing.

Manual background Do not touch electrically live parts.

Manual background Keep guards in place.

Manual background Keep away from moving parts.

Only qualified personnel should install,use or service this equipment.

14PIN AMPHENOL

CAUTION :

TO WORK

ELECTRODE

TO LN-25 INPUT

CABLE PLUG

K626-XX INPUT CABLE ASSEMBLY

ELECTRODE CABLE

TO WIRE FEED UNIT

TO WORK

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

THE ENGINE WELDER OPERATING MANUAL.

N.A. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE RANGE SWITCH TO A WIRE WELDING-CV POSITION. PLACE WELDER TERMINALS SWITCH TO "REMOTELY CONTROLLED" POSITION.

N.B. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE APPLICATIONS. SEE OPERATING MANUAL.

N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITIION. N.D. PLACE IDLER SWITCH IN "AUTO" OR "HIGH" IDLE POSITION AS DESIRED.

6-20-97

S23732-3

RANGER 300 DLX / LN-7 CONNECTION DIAGRAM

Manual background WARNING

Do not operate with panels open.

Disconnect NEGATIVE (-) BATTERY LEAD

before servicing.

Do not touch electrically live parts.

Manual background Keep guards in place.

Manual background Keep away from moving parts.

Manual background Only qualified personnel should install,use or service this equipment.

14PIN AMPHENOL

6PIN AMPHENOL

CAUTION :

TO WORK

ELECTRODE

TO LN-7 INPUT

CABLE PLUG

K584 CONTROL CABLE

OPTIONAL K857 REMOTE CONTROL

ELECTRODE CABLE

TO WIRE FEED UNIT

TO WORK

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

THE ENGINE WELDER OPERATING MANUAL.

N.A. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE APPLICATIONS. SEE OPERATING MANUAL.

N.B. USE POLARITY SWITCH TO SELECT DESIRED ELECTRODE POLARITY. POSITION THE RANGE SWITCH TO A WIRE WELDING-CV POSITION. N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE LOCAL REMOTE SWITCH IN "REMOTE" POSITION.

N.D. PLACE IDLER SWITCH IN "HIGH" POSITION.

6-20-97

S23732-4

RANGER 300 D AND 300 DLX

Page 42
Image 42
Lincoln Electric 300 DLX manual F-2CONNECTION DIAGRAMSF-2