CONNECTION DIAGRAMS | ||
|
|
|
RANGER 300 D / LN-7 / K240 CONTACTOR KIT
WARNING
Do not operate with panels open.
Disconnect NEGATIVE
Do not touch electrically live parts.
Keep guards in place.
Keep away from moving parts.
Only qualified personnel should install,use or service this equipment.
CONTROL CABLE
N.D.
CONNECT THE CONTROL CABLE GROUND LEAD TO THE FRAME TERMINAL MARKED NEAR THE TERMINAL STRIP OR TO AN UNPAINTED FRAME SCREW.
21 | GND. | 32 |
| 2 | 4 | 31 |
N.C. | N.B. |
|
|
|
|
|
| POWER | 32 | 2 | 4 |
| 31 |
| SOURCE |
|
TO
K240 CONTACTOR KIT
115V (50/60HZ.)
(NOTE : 600 AMP CAPACITY)
N.F. & N.G. |
|
N.J. |
|
6 PIN AMPHENOL | WORK ELECTRODE |
|
WELDER STANDARD OUTPUT TERMINALS
AUTO.
EQUIP.
POWER
SOURCE
ELECTRODE CABLE TO
TO WORK
N.A. USE POWER SOURCE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH ON THE POWER SOURCE TO THE CV POSITION.
N.B. 3 CONDUCTOR #16 POWER CORD PHYSICALLY SUITABLE FOR THE INSTALLATION AND PLUG RATED AT 115 VOLTS 15 AMPERES AC.
N.C. PLUG INTO 115 VOLT AC RECEPTACLE ON WELDER CONTROL PANEL OR OTHER 115 VOLT AC SUPPLY RATED AT A MINIMUM OF 500 VOLT AMPERES.
N.D. LEADS #21 AND GND. DO NOT APPEAR ON
N.E. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE APPLICATIONS. (SEE OPERATOR’S MANUAL.)
N.F. IF
N.G. TAPE UP BOLTED CONNECTION WHERE LEAD #21 IS EXTENDED.
N.H. IDLER SWITCH ON POWER SOURCE MUST BE IN HIGH IDLE POSITION.
N.J. IF AN OPTIONAL K857 REMOTE OUTPUT CONTROL IS USED, CONNECT IT TO THE RANGER 300 D AMPHENOL CONNECTOR.
NOTE: PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITION WHEN REMOTE OUTPUT CONTROL IS USED.
CAUTION: ANY SPEED UP OF THE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES ABOVE 140 VOLTS, THE
RANGER 300 D AND 300 DLX