Lincoln Electric 300 DLX manual Connection Diagrams

Models: 300 D

1 56
Download 56 pages 9.16 Kb
Page 43
Image 43
CONNECTION DIAGRAMS

F-3

CONNECTION DIAGRAMS

F-3

 

 

 

RANGER 300 DLX / LN-742 CONNECTION DIAGRAM

Manual background WARNING

Manual background Do not operate with panels open.

Manual background Disconnect NEGATIVE (-) BATTERY LEAD before servicing.

Manual background Do not touch electrically live parts.

Manual background Keep guards in place.

Manual background Keep away from moving parts.

Manual background Only qualified personnel should install,use or service this equipment.

14 PIN AMPHENOL

TO WORK

ELECTRODE

TO LN-742 INPUT

CABLE PLUG

K592 CONTROL CABLE

ELECTRODE CABLE TO WIRE FEED UNIT

CAUTION :

TO WORK

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

THE ENGINE WELDER OPERATING MANUAL.

N.A. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE APPLICATIONS. SEE OPERATING MANUAL.

N.B. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE RANGE SWITCH TO A WIRE WELDING-CV POSITION. N.C. PLACE WELDER TERMINALS SWITCH TO "REMOTELY CONTROLLED" POSITION.

N.D. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITIION. N.E. PLACE IDLER SWITCH IN "AUTO" OR "HIGH" IDLE POSITION AS DESIRED.

6-20-97

S23732-5

RANGER 300 DLX / LN-8 CONNECTION DIAGRAM

Manual background WARNING

Manual background Do not operate with panels open.

Manual background Disconnect NEGATIVE (-) BATTERY LEAD before servicing.

Manual background Do not touch electrically live parts.

Manual background Keep guards in place.

Manual background Keep away from moving parts.

Manual background Only qualified personnel should install,use or service this equipment.

TO LN-8 INPUT

CABLE PLUG

K595 CONTROL CABLE

14PIN AMPHENOL

TO WORK

ELECTRODE

ELECTRODE CABLE

TO WIRE FEED UNIT

CAUTION :

TO WORK

 

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

THE ENGINE WELDER OPERATING MANUAL.

N.A. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE APPLICATIONS. SEE OPERATING MANUAL.

N.B. USE POLARITY SWITCH TO SELECT DESIRED ELECTRODE POLARITY. POSITION THE RANGE SWITCH TO A WIRE WELDING-CV POSITION. PLACE LOCAL / REMOTE SWITCH IN "REMOTE" POSITION.

N.C. PLACE IDLER SWITCH IN "HIGH" POSITION.