CONNECTION DIAGRAMS

F-5

 

 

 

 

RANGER 300 DLX / K930-1 TIG MODULE / CONNECTION DIAGRAM

 

Manual background WARNING

REGULATOR FLOWMETER

ARGON GAS CYLINDER

CAUTION :

Do not operate with panels open.

Keep guards in place.

Disconnect NEGATIVE (-) BATTERY LEAD

Keep away from moving parts.

before servicing.

Only qualified personnel should install,use

Do not touch electrically live parts.

or service this equipment.

TO GAS

INPUT

FITTING

K936-1

 

K870 FOOT AMPTROL

CONTROL CABLE

 

-OR-

 

 

TO WORK

 

K963-1 HAND AMPTROL

 

14 PIN

-OR-

 

AMPHENOL

 

K814 ARC START SWITCH

 

 

 

ELECTRODE

 

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

THE ENGINE WELDER OPERATING MANUAL.

N.A. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE APPLICATIONS. SEE OPERATING MANUAL.

N.B. USE POLARITY SWITCH TO SELECT DESIRED ELECTRODE POLARITY. POSITION THE RANGE SWITCH TO A "STICK/WELD" POSITION. N.C. PLACE WELDER TERMINALS SWITCH TO " REMOTELY CONTROLLED" POSITION.

N.D. PLACE OUTPUT CONTROL SWITCH IN "REMOTE CONTROL" POSITION. N.E. PLACE IDLER SWITCH IN "AUTO" OR "HIGH" IDLE POSITION AS DESIRED.

6-20-97

S23732-9

RANGER 300 D / K930-1 TIG MODULE WITH K938-1 CONTACTOR KIT / CONNECTION DIAGRAM

Manual background WARNING

REGULATOR FLOWMETER

Do not operate with panels open.

Keep guards in place.

Disconnect NEGATIVE (-) BATTERY LEAD

Keep away from moving parts.

before servicing.

Only qualified personnel should install,use

Do not touch electrically live parts.

or service this equipment.

ARGON GAS CYLINDER

CAUTION :

TO GAS

INPUT

FITTING

K963-3 Manual background

CONTROL CABLE

TO WORK

Manual backgroundManual background 6 PIN Manual backgroundManual backgroundManual backgroundManual backgroundAMPHENOL

ELECTRODE

K870 FOOT AMPTROL

-OR-

K963-1 HAND AMPTROL

-OR-

K814 ARC START SWITCH

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

THE ENGINE WELDER OPERATING MANUAL.

N.A. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE APPLICATIONS. SEE OPERATING MANUAL.

N.B. USE POLARITY SWITCH TO SELECT DESIRED ELECTRODE POLARITY. POSITION THE RANGE SWITCH TO A "STICK/WELD" POSITION.

N.C. PLACE OUTPUT CONTROL SWITCH IN "REMOTE CONTROL" POSITION. N.D. PLACE IDLER SWITCH IN "HIGH" IDLE POSITION.

CRM after 9-23-97

S23732-10

RANGER 300 D AND 300 DLX