A-5

A-5

INSTALLATION

Figure A.9 is a connection diagram for connecting the LN-9 GMA to V300 power sources. The connection is made with a K596 cable assembly, which has an amphenol connection rather than a terminal strip con- nection at the power source.

Depending on the power source and process you are using, the jumpers on the LN-9 GMA voltage board may have to be changed. As shipped, the LN-9 GMA is connected for use with the DC-250 DC-400, CV-400, CV-500-I and DC-600. For other power sources, refer to the appropriate connection diagram.

NOTE: If you are using the Pulse Power 500, DC650 Pro, or V300 power source, the K442-1 Pulse Power Filter Kit must be installed in the LN-9 GMA. See the instructions included with the kit. If you are using the Invertec V300, the K608-1 Adapter must also be installed according to the connection diagram and instructions provided in the Invertec Manual.

LN-9 GMA and LN-9F GMA Wire Feeder

Page 14
Image 14
Lincoln Electric LN-9F GMA, LN-9 GMA manual Installation