OPERATION

VOLTAGE CONTROL RESPONSE

The LN-9 GMA is provided with selectable voltage con- trol response. Proper setting depends on the power source and process being used. Refer to the appropri- ate power source connection diagram for the proper connection of the jumpers located on the LN-9 GMA Voltage Board.

To change the voltage control response:

a)Turn OFF the control power to the LN-9 GMA at the power source.

b)Remove the screws holding the control section cover in place and swing open.

c)Position the jumper plugs on the Voltage Board according to the appropriate power source con- nection diagram.

d)Reassemble.

STARTING CHARACTERISTICS

SELECT ACCELERATION

The LN-9 GMA models can provide optimum starting for different processes. The wire feeder is designed to start with two different speeds of controlled acceler- ation. As shipped, it is connected for fast acceleration, which is the best for most open arc procedures. However, the slower acceleration may be more desir- able for long stickout applications and most submerged arc procedures. If the electrode being used does not give satisfactory starting because of "stubbing" or "blasting off," slower acceleration can be obtained by modifying the LN-9 GMA models as follows:

a)Turn OFF the control power to the LN-9 GMA at the power source.

b)Remove the screws holding the control section cover in place and swing it open.

c)On machines having an L7253 Control PC board, move the jumper plug on the PM Control PC board from pin "F" to pin "S."

On machines having an L10068 Control PC board, set the DIP switch on the PM Control PC board to the “S” position.

d)Reassemble.

START VOLTAGE TRIM

The start voltage is the voltage provided by the welding power source before establishing the welding arc. This start voltage setting is a function of the open circuit voltage characteristic of the power source, the SET value of the weld voltage, and the start voltage trimmer (R41) setting on the LN-9 Voltage PC Board. As set at the factory, the start voltage trim level is typically about 20% higher than the LN-9 GMA SET level. This gen- erally gives good starting for steel cored and MIG processes using CO2 or Argon/CO2 blended shielding gas. If you are using "hotter" gases (such as Argon/Oxygen blends) and other processes (such as stainless steel MIG), arc flaring may occur at start, which requires lowering the start voltage trim as fol- lows:

a)Turn off the control power to the LN-9 GMA at the power source.

b)Remove the screws holding the control section cover in place and swing it open.

c)On the voltage board, locate trimmer R41 (below R40 next to the 1/8 amp fuse) and labeled START.

d)The slot on the START trimmer is marked with a red seal for factory setting. To decrease the facto- ry setting, turn the slot CCW (opposite to the labeled arrow direction).

NOTE: If the start trim is set too low, stubbing may occur at start, requiring increasing the START trimmer by turning the slot CW (in the direc- tion of the labeled arrow).

e) Re-assemble.

RUN-IN FEATURE

On new machines (above code 10350) a “Run-in” trim- mer, labeled “RUN-IN,” is provided on the new L10068- 1 Control PC board.

This trimmer can be used to set the run-in wire feed speed as a percentage of the weld speed. When the trimmer is turned fully counterclockwise, the run-in speed is about 5% of the weld speed. When the trim- mer is turned fully clockwise, the run-in speed is equal to the weld speed. To increase the run-in speed, turn the trimmer clockwise; and to decrease the run-in speed, turn the trimmer counterclockwise.

The factory setting of the run-in trimmer is about 20%. The trimmer should be set lower if arc starting tends to stub or blast, and it should be set higher if the arc tends to flare up. When the Actual button is pressed, the actual speed setting can be viewed on the digital speed meter for two seconds after closing the trigger or the cold inch switch.

LN-9 GMA and LN-9F GMA Wire Feeder