TROUbLESHOOTING

Observe Safety Guidelines

detailed in the beginning of this manual.

TROUbLESHOOTING GUIDE

PRObLEMS (SYMPTOMS)

Gun trigger will not feed wire. Digital meter is not lit.

POSSIbLE AREAS OF

MISADJUSTMENT(S)

WIRE FEEDING PRObLEMS

1.Check to see if the circuit breaker is tripped. Reset the circuit breaker. See the topic "Circuit Breaker" in the Operation section.

2.Check to see if the power supply fuse is blown. Replace the fuse. See the topic "Power Supply Fuse" in the Operation section.

3.Check to see if there is 115 VAC supply from the power source. Check that power source is "on". If so, check the power source AC fuse.

4.The control cable may be faulty. Check or replace.

RECOMMENDED

COURSE OF ACTION

If all recommended possible areas of misadjustment have been checked and the problem persists, contact your local Lincoln Authorized Field Service Facility.