F-11

TROUBLESHOOTING AND REPAIR

F-11

MAIN TRANSFORMER TEST

WARNING

Service and repair should only be performed by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed. Call 1-800-833- 9353(WELD).

TEST DESCRIPTION

This test will determine if the correct voltages are being applied.

a.Applied to the primary windings of the main transformers.

b.Induced on the secondary and auxiliary windings of the main transformer.

MATERIALS NEEDED

3/8” Nutdriver

5/16” Nutdriver

Volt-ohmmeter

This procedure takes approximately 40 minutes to perform.

POWER MIG 200

Page 45
Image 45
Lincoln Electric SVM157-A service manual Main Transformer Test, Test Description, Materials Needed