Lincoln Electric SVM157-A service manual Contactor Test

Models: SVM157-A

1 91
Download 91 pages 49.54 Kb
Page 55
Image 55

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-21

TROUBLESHOOTING AND REPAIR

F-21

CONTACTOR TEST

WARNING

Service and repair should only be performed by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed. Call 1-800-833- 9353(WELD).

TEST DESCRIPTION

This test will determine if the contactor is functional.

MATERIALS NEEDED

12 VDC Supply

Volt/Ohmmeter

7/16” Wrench

This procedure takes approximately 30 minutes to perform.

POWER MIG 200

Page 55
Image 55
Lincoln Electric SVM157-A service manual Contactor Test