TROUBLESHOOTING AND REPAIR

F-11

Observe Safety Guidelines detailed in the beginning of this manual.

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

PROBLEMS

(SYMPTOMS)

The welding arc is “cold.” Engine runs normally (3700 RPM no load). Auxiliary power is functioning nor- mally.

POSSIBLE AREAS OF

MISADJUSTMENT(S)

WELDING PROBLEMS

1.Check for loose or faulty connec- tions at the weld output terminals and welding cable connections.

2.The welding cable may be too long or coiled, causing an exces- sive voltage drop.

RECOMMENDED

COURSE OF ACTION

1.Check for the correct open cir- cuit voltage (OCV) at the welder output terminals (80VAC Max. 72VDC Max.). If the correct voltage is present at the output terminals, then check for loose

connections on the heavy cur-

DiagramEAGLE 8. See Wiringthe

.rent carrying leads inside

2.If the OCV is low at the welder outputThe Engineterminals,ThrottlethenAdjustmentPerform Test.

3.BridgePerformTestthe. Output Rectifier

4.Check for shorted or grounded windings in the reactor andWiringalso Diagramin the ain stator. See

Return to Section TOC

Return to Master TOC

WELDING PROBLEMSCAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.

EAGLE™ 10,000