Lincoln Electric SVM192-A Auxiliary Power, 120/240 VOLT DUAL VOLTAGE RECEPTACLE, Motor Starting

Models: SVM192-A

1 94
Download 94 pages 62.44 Kb
Page 13
Image 13
AUXILIARY POWER

Return to Section TOC

Return to Master TOC

A-7

INSTALLATION

 

 

 

 

A-7

AUXILIARY POWER

 

 

 

 

 

 

 

 

 

 

GND

 

 

 

 

 

 

 

 

 

 

The EAGLE 10,000 can provide up to 9,000 watts of

 

 

 

 

 

 

 

 

 

 

 

 

 

120/240 volts AC, single phase 60Hz power for contin-

 

 

 

 

 

uous use, and up to 10,000 watts of 120/240 volts AC,

 

 

 

 

 

single phase 60Hz power peak use. The front of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

machine includes three receptacles for connecting the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC power plugs; one 50 amp 120/240 volt NEMA 14-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50R receptacle and two 20 amp 120 volt NEMA 5-20R

 

 

 

 

 

 

 

120 V

loads up to rated capacity. See

Table I for more infor-

 

 

 

 

 

 

 

 

 

receptacles. Output voltage is

within +/-10% at all

 

 

 

 

 

 

 

240 V

 

 

 

 

 

 

 

 

 

 

 

mation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120 V*

120/240 VOLT DUAL VOLTAGE RECEPTACLECAUTION

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Do not connect any plugs that connect to the power receptacles in parallel.

------------------------------------------------------------------------

Start the engine and set the “IDLER” control switch to the desired operating mode. Set the “CONTROL” to

10.Voltage is now correct at the receptacles for auxil- iary power.

120/240 VOLT DUAL VOLTAGE RECEPTACLE

The 120/240 volt receptacle can supply up to 38 amps of 240 volt power to a two wire circuit, up to 38 amps of 120 volts power from each side of a three wire cir- cuit (up to 76 amps total). Do not connect the 120 volt circuits in parallel. Current sensing for the automatic idle feature is only in one leg of the three wire circuit as shown in the following column.

*Current Sensing for Automatic Idle. (Receptacle viewed from front of Machine)

120 V DUPLEX RECEPTACLES

The 120V auxiliary power receptacles should only be used with three wire grounded type plugs or approved double insulated tools with two wire plugs.

The current rating of any plug used with the system must be at least equal to the current load through the associated receptacle.

MOTOR STARTING

Most 1.5 hp AC single phase motors can be started if there is no load on the motor or other load connected to the machine, since the full load current rating of a

1.5hp motor is approximately 20 amperes (10 amperes for 240 volt motors). The motor may be run at full load when plugged into only one side of the duplex receptacle. Larger motors through 2 hp can be run pro- vided the receptacle rating as previously stated is not exceeded. This may necessitate 240V operation only.

Return to Section TOC

Return to Master TOC

EAGLE 10,000 Extension Cord Length Recommendations

(Use the shortest length extension cord possible sized per the following table.)

Current

Voltage

Load

 

 

Maximum Allowable Cord Length in ft. (m) for Conductor Size

 

 

(Amps)

Volts

(Watts)

14 AWG

12 AWG

10 AWG

8 AWG

6 AWG

4 AWG

15

120

1800

30

(9)

40

(12)

75

(23)

125

(38)

175

(53)

300

(91)

20

120

2400

 

 

30

(9)

50

(15)

88

(27)

138

(42)

225

(69)

15

240

3600

60

(18)

75

(23)

150

(46)

225

(69)

350

(107)

600

(183)

20

240

4800

 

 

60

(18)

100

(30)

175

(53)

275

(84)

450

(137)

38

240

9000

 

 

 

 

50

(15)

90

(27)

150

(46)

225

(69)

 

 

 

 

Conductor size is based on maximum 2.0% voltage drop.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 