PROBLEMS

(SYMPTOMS)

No auxiliary power, welding output is normal. Engine runs normally.

POSSIBLE AREAS OF

MISADJUSTMENT(S)

OUTPUT PROBLEMS

1.If machine is equipped with cir- cuit breakers, check circuit breakers CB1 thru CB5. Reset if tripped.

2.Make sure the Output Control (R1) is set at the maximum posi- tion.

3.Check for loose or faulty plug(s) at the power receptacle(s).

RECOMMENDED

COURSE OF ACTION

1.Check the auxiliary power receptacles and associated wires for loose or faulty connec-

tions.

2. Perform the Auxiliary and

Field Winding Voltage Test.

3. If machine is equipped with cir- cuit breakers, check for faulty breakers and loose or faulty connections on associated wiring.

Return to Section TOC

Return to Master TOC

POSSIBLE AREAS OFCAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.