TROUBLESHOOTING AND REPAIR

F-34

NORMAL OPEN CIRCUIT DC WELD VOLTAGE WAVEFORM (CC MODE)

HIGH IDLE - NO LOAD - OUTPUT CONTROL AT MAXIMUM

CH1

0 volts

50 volts

5 ms

This is the typical DC output voltage generated from a properly operating machine. Note that each vertical divi- sion represents 50 volts and that each horizontal division represents 5 milliseconds in time.

Note: Scope probes connected at machine output terminals.

SCOPE SETTINGS

Volts/Div

50V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 