English Manual
LINDY KVM Extender C5 PRO-300 Installation and Use page 9
REMOTE Switch 1
OFF: Normal operation.
ON: (Before power is applied) Places the REMOTE module into flash upgrade mode so that the internal
software can be changed. (See section 6. Flash upgrade procedure)
Note: When shipped, all switches are set in the OFF positions and this will produce normal operation.
REMOTE Switches 2 and 3
Switches 2 and 3 determine which two keyboard keys (when pressed in unison) are to be designated as
‘hotkeys’. Hotkeys signal to the REMOTE module that the next key to be pressed is a special configuration
command for the module and is not to be passed to the computer system.
2 OFF Hotkeys = CTRL and SHIFT
3 OFF
2 OFF Hotkeys = ALT and SHIFT
3 ON
2 ON Hotkeys = CTRL and ALT
3 OFF
2 ON Hotkeys disabled
3 ON
REMOTE Switch 4
Reserved for future use