Lochinvar 000 through 2 Wiring Diagram continued, 1,500,000 - 1,300,000 - 2,000,000 Btu/hr Models

Models: 000 through 2 1

1 80
Download 80 pages 59.46 Kb
Page 79
Image 79
Wiring Diagram (continued)

Wiring Diagram (continued)

1,500,000 - 1,300,000 - 2,000,000 Btu/hr Models

WARNING:To avoid possible shock hazard, disconnect power before servicing. GY HOT IGNITIONMODULE

BK

 

 

 

W

 

 

 

Y

 

 

 

BL

 

 

 

BR

 

 

Y

LOUVER

COM

RELAY

 

GY

 

 

 

GY

FC-FC+

 

 

5

 

 

BK

S1

ENI

 

4

 

 

L1

L

 

 

 

 

R

BR

BR

 

 

 

 

NO

BK

LOUVER

 

 

 

 

STD.

RELAY

 

 

BK

CONTACTS

 

IGNITION

 

 

MODULE

 

F2 F1

BR

BL

 

SURFACE

GY

 

IGNITER

 

W

 

GY

GY

 

COMMUNICATION

 

BL

CABLE #1

O

 

24 VAC

 

 

Y

 

 

 

LAR

2

TU

L2

EN

1

 

S2/FS

 

11

N/A

10

TH

9

PI

8

LV2

-

+

STATUS

LED

Y

BL/BK

J3

3 2 STATUS 1 SWITCH

O/BK

P

U

FLOW

 

SWITCH

 

C

NO

O

O

 

NC

 

 

PU

 

OPTIONAL

 

Low

High

O

Gas

Gas

 

 

NC

O

NO O/ C

C

 

 

BK

NO

 

NC

 

 

 

PU

 

PU

AIR

Blocked

 

Louver

BL

SWITCH

 

 

Drain

Proving Sw

T

 

NO

NO

 

C

NO

 

 

C

 

 

 

C

W

BR

 

 

T

BK

 

 

NC

 

O

 

NC

 

 

 

 

NC

 

OPTIONAL

 

R

 

 

 

 

 

PU

 

 

TOGGLE

 

 

 

 

MANUAL

 

 

SWITCH

OVERRIDE

 

PU

 

 

 

 

PU

 

 

 

 

C

1

2

 

 

 

 

Y

 

 

7

 

RESET

 

 

 

6

 

LV1

R

 

 

5

 

MV

 

 

4

 

PS

 

 

 

3

 

FF

 

 

 

2

 

M/S

 

 

 

1

 

FF

 

 

 

W R BK

WBK R

 

 

 

1

2

3

4

3

2

 

 

 

1

2

3

BYPASS

W

 

 

VALVE

 

 

 

 

 

 

BL

 

IGNITION

 

RESET

R

24VAC GAS

 

 

VALVE

R

Y

R

GAS VALVE RELAY

 

OR LBL90002 REV A AT OPENManual backgroundManual background

BL

W/BK

Y

R

R

Y

R

 

OPTIONAL

3J

 

 

51

 

41

UOT

31

mV/a

21

 

11

mV/a

01

MH

9

O

 

COMMUNICATION

CABLE #1

COMMUNICATION

CABLE #2

 

INPUTS

 

1

PU

1

 

2

PU

3

PU

4

PU

5

Y

 

PU

50 Hz Limit

Resistor

Y

1.2K Ohm

P

 

OPTIONAL

TO VFD

TO VFD

TERMINAL

TERMINAL

NUMBER 14

NUMBER 15

OPTIONAL 50 Hz LIMIT RESISTOR

CONTROL PANEL COMMUNICATION CABLE CONNECTION

COM

BK

COM

BK

NO

VENT VALVE

 

BK

W

 

 

EXT. GAS VALVE

 

120VAC GAS

NO

VALVE

W

BK

 

Y

 

8

 

 

3

 

 

 

 

 

 

M

 

 

 

 

 

 

 

 

BYPASS SENSOR

7

 

 

 

 

 

 

 

 

HO

BYPASS

2

 

1

2

 

 

 

 

 

 

 

MOH

6

1

 

1

 

1

 

SENSOR

 

 

 

 

 

 

 

 

 

OA

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

SENSOR

 

 

M

 

 

 

 

 

 

 

4

1

 

 

1

 

 

1

 

 

HO

2

 

2

 

2

 

 

 

 

 

 

 

 

 

 

3

 

1

 

 

1

 

 

1

OUTLET SENSOR

 

2

ENABLE

 

INLET

 

 

 

 

 

 

OUTLET

ND

1

SWITCH

 

SENSOR

 

SENSOR

G

 

G

BK

 

BK

 

 

 

 

 

 

 

 

 

 

 

 

CHASSIS

 

 

 

 

RUN/STOP SWITCH

 

GROUND

 

 

 

 

 

 

 

 

2

2

OA SENSOR

 

1

1

OPTIONAL

 

 

2

2

INLET SENSOR

 

1

1

 

COMMUNICATION CABLE #3

REAR COMMUNICATION CABLE CONNECTION

NOTE: DO NOT DISCONNECT

CABLE FROM BLOWER.

 

 

 

 

T

IO

N

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

T

 

 

 

 

 

 

 

 

 

 

 

O

 

 

M

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

O

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

T

 

 

 

 

 

 

 

 

 

 

O

I

 

 

 

 

 

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLOWER

ASSEMBLY

Y

Y

UVERS

COMMON

CLOSED INPUT

OPEN INPUT

LOUVER

CONTACTS

EXT. GAS

INLET

SENSOR

 

VALVE

 

2

1

1

BK

 

 

2120VAC

3OUT

4

W

BLOCKED

DRAIN

1

2

3

T PU BR

NMO MCO

KEDBLOC

PENO

NOTES:

(1)WARNING: To avoid possible shock hazard, disconnect power before servicing.

(2)Where possible, switches and circuitry are shown in power off state.

(3)When replacing wiring, use wire of equal or higher temperature and gage.

(4)Schematic shows electrical connections only. Please refer to wiring diagram in owner's manual for routing and pin-outs for all connector blocks.

(5)Pump delay is standard on water heaters.

LBL90002 REV A

79

Page 79
Image 79