Lochinvar 402 - 2072 Ratings, NOTICE Notes, Copper-finII I=B=R Rating, Other Specifications

Models: 402 - 2072

1 80
Download 80 pages 43.41 Kb
Page 8
Image 8
Ratings

Ratings

Copper-fin II

I=B=R Rating

Model Number

Input

 

Gross

Net

 

Output

I=B=R

 

MBH

 

MBH

Ratings

 

(Note 4)

 

 

Water,

 

 

 

MBH

Note: Change “N” to

 

 

 

 

 

 

 

 

 

“L” for L.P. gas models.

Min

 

Max

(Note 1)

(Note 2)

 

 

 

 

 

 

CFN0402

250

 

399

339

295

 

CFN0502

250

 

500

425

370

CFN0652

250

 

650

553

481

CFN0752

250

 

750

638

555

CFN0992

360

 

990

842

732

CFN1262

360

 

1260

1071

931

CFN1442

360

 

1440

1224

1064

CFN1802

360

 

1800

1530

1330

CFN2072

630

 

2070

1760

1530

CHN0402

250

 

399

339

295

CHN0502

250

 

500

425

370

CHN0652

250

 

650

553

481

CHN0752

250

 

750

638

555

CHN0992

360

 

990

842

732

CHN1262

360

 

1260

1071

931

CHN1442

360

 

1440

1224

1064

CHN1802

360

 

1800

1530

1330

CHN2072

630

 

2070

1760

1530

 

 

 

 

 

 

Installation & Operation Manual

Other Specifications

Appliance

 

 

Air / Vent

Water

Water

Gas

Sizes

Content

Connections

Connections

 

Gallons

 

 

(Note 3)

 

 

 

 

 

 

 

1.6

2"

1-1/4"

6"

1.7

2"

1-1/4"

6"

2.0

2"

1-1/4"

8"

2.1

2"

1-1/4"

8"

2.2

2-1/2"

2"

10"

2.6

2-1/2"

2"

12"

2.9

2-1/2"

2"

12"

3.3

2-1/2"

2"

12"/14"

3.6

2-1/2"

2"

12"/14"

 

 

 

 

1.6

2"

1-1/4"

6"

1.7

2"

1-1/4"

6"

2.0

2"

1-1/4"

8"

2.1

2"

1-1/4"

8"

2.2

2-1/2"

2"

10"

2.6

2-1/2"

2"

12"

2.9

2-1/2"

2"

12"

3.3

2-1/2"

2"

12"/14"

3.6

2-1/2"

2"

12"/14"

 

 

 

 

NOTICE

Notes:

Maximum allowed working pressure is located on the rating plate.

1.The ratings are based on standard test procedures prescribed by the United States Department of Energy.

2.Net I=B=R ratings are based on net installed radiation of sufficient quantity for the requirements of the building and nothing need be added for normal piping and pickup. Ratings are based on a piping and pickup allowance of 1.15.

3.Copper-fin II’s require special gas venting. Use only the vent materials and methods specified in the Copper-fin II Installation and Operation Manual.

4.The Copper-fin II is orificed for operation up to 2000 feet altitude, and including up to 4,500 feet, with no field adjustments. The appliance will de-rate by 4% for each 1000 feet above sea level up to 4,500 feet. Consult the factory for installations above 4,500 feet elevation.

8

Page 8
Image 8
Lochinvar 402 - 2072 operation manual Ratings, NOTICE Notes, Copper-finII I=B=R Rating, Other Specifications