Lochinvar 502, 2072 Operating information, Installation & Operation Manual, Access modes, User

Models: 2072 502

1 68
Download 68 pages 54.37 Kb
Page 54
Image 54
Access modes

Installation & Operation Manual

7 Operating information

Access modes

User

The user can adjust the space heating target temperature and the tank target temperature (if a tank sensor is used) by using the UP and DOWN buttons (FIG. 7-1) at any time during normal operation. By entering the USER code (0704), the user can also change temperature units, time and date, and night setback settings. In User Mode, the following parameters can be viewed but not changed:

Pool water target temperature

Appliance model number

Software version

Total operating hours

Total cycles

Installer

Most parameters are available only to the installer, accessible only by entering the installer access code, see the Copper-fin2Service Manual.

Saving parameters (reference the Parameter Table in the Copper-fin2Service Manual)

To save parameters and exit programming:

Press the ENTER/RESET button, then the MENU/EXIT button 3 times.

To keep parameter settings only for a current operating cycle:

Press the MENU/EXIT button 3 times after making all desired parameter changes.

To enter a parameter and continue programming:

Press the MENU/EXIT button 1 time to return to the parameter listings; press again to return to the menu listings. Remember to press the ENTER/RESET button when finished programming in order to save the changes made.

See the Copper-fin2Service Manual for a detailed description of parameters and access modes.

User 54 Installer

Page 54
Image 54
Lochinvar 502, 2072 operation manual Operating information, Installation & Operation Manual, Access modes, User, Installer