Configuration
ALARM SETUP
[CHANNEL]
Select the channel to be setup.
[INPUT]
Set up the Alarm input format.
NORMAL CLOSE- when the alarm is triggered, alarm output becomes open circuit.
NORMAL OPEN- when the alarm is triggered, alarm output becomes close circuit.
[DURATION]
For both
(1~99 seconds).
NOTE: Alarm output can be triggered by both alarm input and video loss.
Alarm output can not be triggered by motion detection.
INTERVAL SETUP
[SEQUENCE SCREEN]
Interval setup for all channels sequential full screen display (Range: 1~99 seconds)
[PIP SCREEN]
Picture in Picture, the
(Range: 1~99 seconds)
[EVENT UPDATE]
In order to avoid the same event (alarm, motion and video loss) recorded from time to time, the event happens within the EVENT UPDATE period will not be recorded.
(Range: 10~990 seconds)
35