Lucent Technologies 117A4 installation instructions Single Carrier Installation Self Test, Control

Models: 117A4

1 54
Download 54 pages 16 Kb
Page 28
Image 28

Model 117A4 Carrier Installation Instructions

Installing a Single Carrier

 

 

 

 

 

 

Single Carrier Installation Self Test

1A single carrier must always function as a control carrier. Wait a few seconds, then check the LED(s) on the right side of the Model 117A4 carrier.

Compare the OUT OF SYNC and CONTROL/EXPANSION LEDs against the top three lines on the “SYNC and CONTROL/EXP LED Codes” label.

2If the OUT OF SYNC LED is lit, power down, wait at least 15 seconds, and then repower the carrier. If the LED is still lit, call for Customer Support as described on the inside cover of this book.

 

OF

SYNC

 

OUT

 

 

CONTROL/

4

EXPANSION

 

3Verify that the carrier’s CONTROL/EXPANSION LED is lit and that its color is green. This is correct for a single-carrier installation.