gAs ConneCtions

warning

Never co NN ect a gas li N e directly to the grill. a pressure regulator must be

i N stalled o N all gas equipme Nt. all local codes require it aN d lyNx supplies the

correct regulator with your grill. removi N g or faili N g to i N stall the pressure regulator caN result i N fire aN d serious perso Nal i Njury aN d will void the war

raNty.

The grill is factory set to use either propane (lP) or

natural gas (nAT). It is critical that the gas you use matches that which the grill was set up for. You can verify that by checking the rating plate

model numbers and gas type. This one is underneath the drip tray.

The rating plate is located in one or more of the following places:

Attached to the underside of the drip tray

o n the heat shield behind the front panel

o n the inside left cabinet wall

Ensure that the gas supplied meets with the minimum pressure requirements. do not operate the grill on any gas other than that for which the grill has been set.

fuel

Wc

 

Wc m in

 

m ax

 

Under

 

Inlet

 

full Load

n at g as

7 in

 

 in

lP

1  in

 

11 in

 

Water column Requirements

Both the regulator and the manifold orifices have been tuned for the type of gas specified on the rating plate.

converting to a different type of gas requires a conversion kit, available from Lynx or from your dealer and must be installed by a qualified techni- cian.

All installation and all instal lation parts must conform to local codes with the n ational e lectrical Code, Ansi/nfPA 70-1990 and the n ational

fuel g as Code, Ansi Z223.1/ nf PA 54 in the u s and CgA- b 149.1/.2 in Canada.

nATurAl gAs

Lynx recommends that only qualified profession- als perform the required plumbing on this product.

To ensure satisfactory per formance, the gas supply line must be sized to ac commodate the total BTU requirements of all the gas- fired equipment that will be connected to that line.

In no case should pipe less than 3/4” inside diameter or 1” outside diameter ever be used to connect this product.

calculate the total BTU output of all equipment and refer to “ indeX: g as s upply line runs” for allowable run distances for ¾ inch pipe. failure to meet these minimum requirements may reduce performance of the grill and any other appliances running on that supply line.

Always keep supply line runs as short as possible.

(see indeX: “ bTu o utput” for specific model ouputs)

canadian installations must conform to CgA- b 149.1/.2 natural gas/propane installa- tion code. (canada)

A gas shut-off valve must be installed in an easily accessible location by a qualified plumber.



Page 32