Lynx Professional Grills L36PSR-1, L54PSFR-1, L42R-1 Troubleshooting your ly nx grill, GrI ll won

Models: L30PSR-1 L27PSR-2 L42R-1 L36R-1 L27-2 L54PSR-1 L54PSFR-1 L42PSFR-1 L30PSFR-1 L36PSR-1 L30R-1 L27PSFR-2 L27FR-2 L27F-2 L27R-2 L42PSR-1 L36PSFR-1

1 48
Download 48 pages 33.15 Kb
Page 19
Image 19

troubleshooting your lynx grill

before you Call:

Please check a few things before you call for service

Is there fuel supplied to the grill?

i s the main shut-off valve open?

Are you using correct type of fuel? (lP or n atural g as) (see indeX: “ g as requirements” for further

details.)

i s your propane cylinder empty? h ave you recently refilled the propane cylinder? i f so, is the connection tight?

h ave you opened the valve on the propane cylinder?

Is the grill plugged in to a live electric circuit?

i f you’ve checked the above items, review the trouble-shooting list below before calling for lynx for service.

grI ll won

leak Test”

Your Lynx grill uses an electric ignition system that does not spark. The igniters should glow constantly when a control knob is pushed in.

first, confirm that the grill is getting electricity by turning on the lights.

C heCK T he igni T ers

Ensure that all burner controls are set to off

Remove the racks and briquette trays.

Watch an igniter as you push in and hold the corresponding control knob. You will need either a small mirror or shiny metal object to see the igniter under its cover.

correct control knob and keep the knob in the off” position)

check the remaining igniters. If igniters don’t glow, proceed with trou bleshooting or match- light the burner.

ch Ec K Th E BUR n ERS

If the igniters are working check to see if gas is reaching the burners by at tempting to match light a burner.

BE cARE f UL! I f Th E burner fAils To igni Te wAiT 5 M inuT es before ATTe MPT ing To igni Te oTher burners ! (See indeX: “Match lighting” for

further details.)

If match lighting doesn’t work, re-check fuel connec- tions for leaks and ensure the supply is of the correct type and is of adequate

If the burner will light with a match, then the igniter may not be functioning correctly. call for service.

If the burner will not match light, and you know you are getting gas, wait for any gas to dissipate and remove the burner and check it for blockages. (see indeX: “Clean

the b rass b urner” for further details.)

yellow flame or gas smell wh I le Coo KI ng

if you s M ell gAs while The grill is o P erAT ing

i MM ediATely Turn off All burners And shuT off The MAin fuel su PP ly

Perfor M A leAK T esT

(see indeX: “ leak Test” for further details.)

CheCK for bloCKAges

(see indeX: “Clean the b rass b urner” for further details.)

19

Page 19
Image 19
Lynx Professional Grills L36PSR-1 Troubleshooting your ly nx grill, Please check a few things before you call for service