Lynx Professional Grills L54PSFR-1, L54PSR-1 FinAl CheCks, LP Connections, Leak test Procedure

Models: L30PSR-1 L27PSR-2 L42R-1 L36R-1 L27-2 L54PSR-1 L54PSFR-1 L42PSFR-1 L30PSFR-1 L36PSR-1 L30R-1 L27PSFR-2 L27FR-2 L27F-2 L27R-2 L42PSR-1 L36PSFR-1

1 48
Download 48 pages 33.15 Kb
Page 34
Image 34

lP Connections

Make sure the lP cylinder valve is fully closed. It is

finAl CheCks

possible for the valve to be open without releasing gas but, as soon as you start con necting the regulator, gas will leak from the connection.

Insert the regulator inlet into the cylinder valve and turn the black coupler clockwise until the coupler is hand tight. do not over-tighten this connec- tion.

To disconnect the coupler, first make sure the main cylinder valve is turned off. g rasp

the coupler and turn counter clockwise. The inlet will then

leAK TesT ing

danger!

To prevent fire or explosion hazard, DO NOT smoke or allow any potential source of ignition (sparks, electri cal arcing, etc) in the area while performing a leak test. Leak tests should be conducted outdoors only. Never conduct a leak test using fire or flame.

Wash off the soapy solution with cold water and dry.

Tighten the loose joint, or replace the faulty part with manufacturer-recommend- ed replacement parts.

do noT attempt to repair the l.P. cylinder valve if it is damaged. The only way to safely resolve a damaged cylinder is to re P lAC e i T.

Repeat the leak test to ensure that no leaks are present.

disengage.

Always leak-test the connec- tion after refilling or exchang- ing lP cylinders. (See I nd EX:

leak Test” for further details.)

gAs line Purging

You should purge the gas line of air before attempting to light the grill.

m ake sure all grill controls are in the “ off ” position.

Slowly turn on the main gas supply.

Push in the rotisserie knob and confirm that the igniter is glowing. It is furthest from the fuel source and will completely purge the lines. It will take several seconds for the burner to light.

h old the knob on for about 20 seconds to allow the air in the system to purge and the burner to light

wait at least 5 minutes after shutting off the control before attempting to light the burners.

leak test Procedure:

create a soapy solution of 1 part soap and  parts water.

Confirm that all control knobs are in the off position.

Turn on the fuel supply. for natural gas, turn the valve handle 1/4 turn to align with the gas flow.

for l.P., turn the cylinder valve knob counter clockwise one full rotation.

Apply the soap solution generously by paint brush or squirt bottle on all con nections and fittings.

If bubbles appear to

“grow” on any of the con- nections, you have a gas leak. I mm Ed IATELY turn off the gas supply.

fixing a gas leak

Shut off the gas supply

Turn all grill controls to the on ” position to purge

the grill of any gas build- up, then turn the controls back “ off ”.

low h eAT burner Ad- JUST m E nT

for maI n b rass burn- ers, Prosear™ and s I de burners!

do not adJ ust the ro-

tIsserI e burner

The main brass burners and side burners on your Lynx grill feature an adjustable low

setting.

f luctuations in gas pressure, gas conversion and even in the quality of the gas itself may affect burner perfor mance at the “ low” setting. It could be either too high or too low.

to adjust the burner low setting:

m ake sure the grill is cool.

Remove racks and briquette trays so that you can see the flames while adjusting the burners.

Light the burner and set it to “ low”. (all the way counter- clockwise).



Page 34
Image 34
Lynx Professional Grills L54PSFR-1, L54PSR-1, L36PSR-1 FinAl CheCks, LP Connections, Leak test Procedure, Fixing a gas leak